Hi Christophe! On 2023-05-09T09:32:55+0200, Christophe Lyon wrote: > On Wed, 3 May 2023 at 13:47, Richard Biener via Gcc-patches wrote: >> On Wed, 3 May 2023, Thomas Schwinge wrote: >> > "Let each 'lto_init' determine the default 'LTO_OPTIONS', and 'torture-init' the 'LTO_TORTURE_OPTIONS'"? > > This is causing issues on arm/aarch64, including: > > ERROR: can't read "LTO_TORTURE_OPTIONS": no such variable > in gcc.target/arm/acle/acle.exp: > > ERROR: torture-init: LTO_TORTURE_OPTIONS is not empty as expected > in gcc.target/aarch64/sls-mitigation/sls-mitigation.exp, > gcc.target/aarch64/sve/acle/aarch64-sve-acle-asm.exp, > gcc.target/aarch64/sve2/acle/aarch64-sve2-acle-asm.exp, > gcc.target/aarch64/torture/aarch64-torture.exp > > and maybe others > > Are other targets affected too? Sorry for that -- it means, the safe-guards I added are working as expected. Please test whether all these issues are gone with the attached "Testsuite: Add missing 'torture-init'/'torture-finish' around 'LTO_TORTURE_OPTIONS' usage"? Grüße Thomas ----------------- Siemens Electronic Design Automation GmbH; Anschrift: Arnulfstraße 201, 80634 München; Gesellschaft mit beschränkter Haftung; Geschäftsführer: Thomas Heurung, Frank Thürauf; Sitz der Gesellschaft: München; Registergericht München, HRB 106955