public inbox for insight@sourceware.org
 help / color / mirror / Atom feed
* General question
@ 2003-08-19  9:37 Hylla, Kai
  2003-08-19 16:04 ` Keith Seitz
  2003-08-19 17:13 ` Peter Reilley
  0 siblings, 2 replies; 11+ messages in thread
From: Hylla, Kai @ 2003-08-19  9:37 UTC (permalink / raw)
  To: insight

Hi!

I'm new to this and I have a generall question. (Hopefully it's not
off-topic)

I try to use insight under win2k using cygwin. I'm building software for
a powerpc-elf target. I try to debugt my software using the wiggler/bdm
interface. I downloaded insight and ocdlibremote from www.ocdemon.com. I
can download the software, examin the memory an set up registers. But I
can't start the software. I set a breakpoint at main and at the very
first opcode and hit continue but insight doesn't stop at the
breakpoint.

Has anyone experiences using insight under win2k with bdm/wiggler
support and give me some advise?

Thanks,
Kai

---
K. Hylla
Abt. NJT T3

ATLAS Elektronik GmbH
A BAE Systems Company
Sebaldsbruecker Heerstr. 235
D-28305 Bremen

Tel.: +49 421 457-3231
Fax : +49 421 457-1702 

^ permalink raw reply	[flat|nested] 11+ messages in thread
* RE: General question
@ 2003-08-20  8:57 Hylla, Kai
  0 siblings, 0 replies; 11+ messages in thread
From: Hylla, Kai @ 2003-08-20  8:57 UTC (permalink / raw)
  To: insight



We use the Motorola MPC561 on a bord that was develop by us.

The code I've written works. At least the initialisation code. It had
been tested with insight 5.0 and it worked fine. The problem is that
insight 5.0 clears the special purpose register 560 every time I do
single stepping. The register is not an chache register as insight
asumes. In the MPC561 it configurates the execption vector table which
is importent for interrupts. So we have to change the debugger.

To make it short:
We decited to use Insight 5.2 with OcdLibRemote under cygwin. As I said
in my last mail I can connect to the bord, set up the necessary
register, download the software and examin the memory. In my oppinion
the connetction between Insight and the MPC561 works. The problem is
that I can't to single stepping, even on assembly level. I set a
breakpoint on the first op-code of the initialisation code and hit
continue. But the breakpoint is never reached...

Any suggestions?

Regards,
Kai 
---
K. Hylla
Abt. NJT T3

ATLAS Elektronik GmbH
A BAE Systems Company
Sebaldsbruecker Heerstr. 235
D-28305 Bremen

Tel.: +49 421 457-3231
Fax : +49 421 457-1702 

^ permalink raw reply	[flat|nested] 11+ messages in thread

end of thread, other threads:[~2003-08-20  8:57 UTC | newest]

Thread overview: 11+ messages (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
2003-08-19  9:37 General question Hylla, Kai
2003-08-19 16:04 ` Keith Seitz
2003-08-19 17:25   ` Peter Reilley
2003-08-19 19:43   ` Rod Boyce
2003-08-19 23:33     ` Peter Reilley
2003-08-19 23:54       ` Rod Boyce
2003-08-20  1:41         ` Keith Seitz
2003-08-20  2:31           ` Peter Reilley
2003-08-20  2:42             ` Keith Seitz
2003-08-19 17:13 ` Peter Reilley
2003-08-20  8:57 Hylla, Kai

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for read-only IMAP folder(s) and NNTP newsgroup(s).